Thermometer Calibration

NVLAP-accredited calibration for your thermometry instruments.

  • Calibration of thermometers, temperature sensors, thermometer probes, thermistors, and thermocouples
  • Traceable to the International System of Units (SI) through the National Institute of Standards and Technology (NIST) or other national metrology institutes
  • Accredited to ISO / IEC 17025 through the National Voluntary Laboratory Assistance Program (NVLAP)

Mail-In Service: Yes
On-Site Service: Yes

 

Choose Masy for Accurate Calibration

Ensuring Measurement Accuracy for your Critical Thermometry Sensors

Accurately-calibrated temperature sensors are critical to the successful operation of pharmaceutical, medical device, and biotechnology companies. When thermometers in your cGLP laboratory and cGMP manufacturing environment are correctly calibrated, the overall integrity and quality of your production chain is greatly improved — helping to keep consumers safe, products effective, and operations profitable.

 

Masy's Approach to Calibration

Masy BioServices’ Approach to Calibration

Masy’s thermometer calibration service offers high-quality calibration uncertainties, traceable to the International System of Units (SI) through the National Institute of Standards and Technology (NIST) or other national metrology institutes.

Mail-in calibrations are performed in our 10,000ft2  environmentally-controlled metrology laboratory, featuring the highest-quality calibration standards and state-of-the-art calibration technology, allowing us to offer minimal measurement uncertainty for your sensitive metrology standards and laboratory instruments.

Masy’s metrology laboratory is meticulously maintained at 21-23°C with 30-55% relative humidity, facilitating repeatable and accurate calibration.

The laboratory’s suite of fixed-point temperature reference cells ranges from -196°C Argon through 1200°C Silver, providing the widest range of commercial metrology capabilities required for your specific needs. Fixed-point or comparison calibrations are available.

On-site field calibration of your fixed instruments offers the same NIST-traceable results, bringing our expertise and equipment to you.


Wide Range of Calibration Capabilities

The Right Range for your Requirements

Our thermometry calibration range is -196°C to 1200°C / -320°F to 2192°F, including fixed points at:

  • -189.3442°C Argon Triple Point

  • -38.8344°C Mercury Triple Point

  • 0.01°C Triple Point of Water

  • 29.7646°C Gallium Melting Point

  • 156.5985°C Indium Freezing Point

  • 231.928°C Tin Freezing Point

  • 419.527°C Zinc Freezing Point


Comprehensive Scope of Equipment Serviced

Comprehensive Scope of Thermometer Calibration

Temperature Sensor Types
  • Resistance Temperature Devices (RTDs)
  • Industrial Thermocouples
  • Thermistors
  • Thermometers
  • Validation Thermocouples
  • Wireless Dataloggers
Temperature Sensor Makes & Models
  • Amphenol
  • Cooper Atkins
  • DataTrace
  • DeltaTrak
  • Fluke
  • Kaye
  • MadgeTech
  • Mesa Labs
  • Omega
  • Onset
  • Pelican
  • Pyromation
  • Thermometrics
  • Thermx
  • Vaisala
List is representative but not completely inclusive; contact us with your specific make & model for a detailed quote.

 


Rigorous Quality Reviews

Rigorous Quality Reviews for Calibration Confidence

Masy BioServices provides calibration services that meet cGMP requirements. Our reviewed and verified calibration documentation provides the critical information you need to support the accuracy requirements of your standards and instruments. Masy’s calibration certificates can include both "as found" and "as left" data, as well as verification that the probes used in your calibrations are in tolerance.

 

Fast Calibration Turnaround Time

Fast Turnaround Time Keeps your Operations On-Schedule

Our normal turn-around times for thermometers and thermometry devices are:

  • Resistance Temperature Devices (RTDs): 1-2 weeks
  • ​Thermistors: 1-2 weeks
  • Thermocouples: 1-2 weeks
  • Thermometers: 1-2 weeks
  • Wireless Dataloggers: 1-2 weeks
 

Contact Masy for Calibration

Choose Masy BioServices for your Thermometry Calibration Needs

When you choose Masy for your thermometer calibration needs, you can enjoy the confidence that comes with knowing that these critical temperature standards are accurately calibrated to the highest possible level of accuracy, ensuring precise thermal measurement in your own laboratory and production environments.
 

Contact Masy BioServices today for your thermometer calibration needs.

 
NVLAP-ILAC
Masy BioServices is one of a select number of metrology laboratories in North America that meets the rigorous qualifications for NVLAP accreditation to ISO 17025:2005.
View our NVLAP Accreditation

Related Products & Services