Validation Equipment Rentals

Masy Systems offers complete validation equipment systems for rent with current NIST traceable and A2LA accredited to 17025 calibrations (where noted A2LA ISO 17025:2005 accredited calibrations for Digi dataloggers, temperature baths and IRTD standards) certificates. Complete systems can include a pre-programmed validation datalogger with thermocouples, pressure or humidity sensors. Also available for rent are validation dataloggers, temperature reference baths, temperature and calibration standards and miscellaneous validation accessories.

Before renting, we encourage all users to read through our Quick Reference Guides to ensure familiarity with handling, using and storing the validation equipment.
  • Validation Dataloggers
    • GE Kaye Validator 2000
    includes 1 SIM (12 channels)
    Validator 2000 software v. 2.30 installed
      Validated V2000 Dataloggers are available as rental units with purchased IQ/OQ Protocol Execution and Documentation. Read about Validated Systems.
    • GE Kaye Portable A2LA ISO 17025:2005 accredited calibrations for Digi dataloggers, temperature baths and IRTD standards Validator
    includes 1 Scanner (16 channels)
    • GE Kaye KL Validator A2LA ISO 17025:2005 accredited calibrations for Digi dataloggers, temperature baths and IRTD standards
    includes 1 Scanner (16 channels)
    • GE Kaye Digistrip 4+ A2LA ISO 17025:2005 accredited calibrations for Digi dataloggers, temperature baths and IRTD standards
    includes 1 Scanner (16 channels)
    • GE Kaye Digi-Link 4+ A2LA ISO 17025:2005 accredited calibrations for Digi dataloggers, temperature baths and IRTD standards
    includes 1 Scanner (16 channels)
    • Additional SIMs and Scanners
    for V2000 or Digi Dataloggers
    • Quick Disconnect Panel
    for Digistrips
    • PC Notebook Workstation
    DOS and WIndows Validator and Validator 2000 software
    v. 2.30 installed
  • Temperature Standards
    • GE Kaye IRTD-400 A2LA ISO 17025:2005 accredited calibrations for Digi dataloggers, temperature baths and IRTD standards
    Range: -196ºC to 400ºC
    Accuracy to ± 0.025ºC
  • Temperature Reference Baths
    • GE Kaye LTR-140 (-25ºC & -40ºC models) A2LA ISO 17025:2005 accredited calibrations for Digi dataloggers, temperature baths and IRTD standards
    Range: -25ºC or -40ºC to 140ºC
    Accuracy: ±0.1ºC to ±0.4ºC
    • GE Kaye HTR-400 A2LA ISO 17025:2005 accredited calibrations for Digi dataloggers, temperature baths and IRTD standards
    Range: Ambient to 400ºC
    Accuracy: ±0.2ºC to ±0.4ºC
    • GE Kaye CTR-80 / Hart Scientific 7380
    Range: -80ºC to 30ºC
      Note that -80ºC baths are large, heavy (125lbs+) and require crating and special handling. We would prefer that the baths be picked up or delivered, but if that is not practical, we will ship as fragile freight. Please contact us for an estimate.
    • GE Kaye 140-4 Ice Point
    Ice Point 0ºC
    Accuracy: ±0.02ºC
    • Hart Portable Furnace 9150
    Range: 150ºC to 1200ºC
    Accuracy: ±5ºC
    • Hart Silicone Oil Bath 7103S*
    Range: -30ºC to 140ºC
    Accuracy: ±0.3ºC
    • Hart Handheld Drywell Bath 9100*
    Range: 35ºC to 300ºC
    Accuracy: ±0.5ºC to ±1.0ºC
    • Hart Handheld Drywell Bath 9102*
    Range: -10ºC to 122ºC
    Accuracy: ±0.5ºC to ±1.0ºC
  • Calibration Standards
    • Rosemount Pressure Transducer
    Range: 0-100 psia
    Accuracy: ± 0.5% of Full Scale
    • International Light, UV Wide-band A
    Range: 0 mW/m² to 14 W/m²
    • International Light, Illuminance
    Range: 0 mLux to 40 KLux
    • Monarch Tach 4 Tachometer
    Optical Range: 1 to 250,000 RPM
  • Miscellaneous
    • Met One Particle Counter (models 2408 and 3423)
    Flow Rate: 1.0 CFM and 1.77 CFM
    Channel Sizes: 0.3 to 10.0 micron particle (varies between models)
    • Thermocouple Feedthrough*
    Designed for Sterilizers/Autoclaves; SS
    • Thermocouple Welder*
    Arc welder for thermocouple tip welding
    • Multimeter
    Measures voltage (AC/DC), current, resistance, capacitance
    • Vaisala HMI31 RH/Temp Meter
    Portable digital meter
    Accuracy: ± 5%RH, ± 2ºC
    • VAPORTRON H100BL/H100CL Series Portable Humidity Lab
    Portable humidity calibrator
    Accuracy: ± 1.5%RH max between 20-90%RH
    • Thermal Range Rover
    Performance testing on shipper containers under precise environmental conditions
    (-30ºC to 60ºC).
  • Validation Sensor Assemblies
    • Relative Humidity Sensor Assembly
    Range: 10%RH to 100%RH, -30ºC to 70ºC 
    • HygroLogger Temperature/RH Assemblies
    Includes Windows software and PC RS-232 cable
    • CO2 Assemblies
    Range: 0%CO2 to 10%CO2
      Relative Humidity Calibration
      • Three Point Ambient RH Calibration (20%, 35% & 85%RH @ 23ºC)
    Accuracy: ± 1.2%RH over range 20%RH to 85%RH @ 23ºC.
      • Specific Point RH Calibration
        @ ICH* Points
    Accuracy: ± 1%RH @ 25ºC/60%RH, 30ºC/60%RH, 30ºC/65%RH,
    30ºC/75%RH (New Point!) , 40ºC/75%RH
      • Specific Point Calibration
        @ customer-defined non-ICH Points
    Accuracy: ± 1%RH @ specific point
      CO2 Calibration
      • Three Point CO2 Calibration
    Calibration @0%CO2, 5%CO2, check at 10%CO2
      • Single Point CO2 Calibration
    Calibration at 5%CO2
      *ICH (The International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use) has set a number of guidelines in regards to temperature and relative humidity control for stability chambers and stability rooms for the pharmaceutical industry. The ICH Q1A Guideline - "Stability Testing of New Drug Substances and Products (Second Revision) " provides recommendations on stability testing protocols including temperature, humidity and trial duration.

     Includes current NIST traceable calibration certificates (except where noted*)

    All equipment undergoes a verification or calibration when received from each rental. In the event of an out of tolerance condition a nonconformance report will be generated and the customer will be notified.

    Rental Terms and Conditions: There is no minimum rental period and equipment will be shipped upon receipt of 1st month's payment (purchase order or credit card payment with 3% administrative fee) and completed credit form for new customers. Each additional month will be billed net 10 days. Equipment rental period starts from day of shipment. Equipment returned within one week is 50% of monthly charge, within two weeks is 75%, within 3 or 4 weeks is 100%. Beyond the first month, a per diem percentage applies until equipment is returned. Customers are responsible for shipping charges and for returning the rented equipment in the same condition as received, except for ordinary wear and tear.

    To request a quote, place an order or receive more information, please:

  • Complete the ENHANCED Quote & Order Form.
  • Refer to our PDF Price List or On-line Price List for details.
  • Download our Rental Equipment Quick Reference Guides.

  •  

     

    Dataloggers Dataloggers

    Validator 2000 Validator 2000

    Digistrip Digi Strip 4

    Portable Validator Portable Validator

    Validation Packages Validation Equipment Rentals

     

     

     

     

     

     

    Relative Humidity Sensor Assembly Relative Humidity Sensor Assembly

     

    HygroLogger
    Assembly Hygrologger Assembly

     

    CO2 Sensor Assembly CO2 Sensor Assembly

     

     

    Thermocouple Feedthrough Assembly & Adaptors Thermcouple Feedthrough Assembly & Adaptors

    (click for details)